We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

We describe the design, construction, calibration, and characterization of a multi-primary high dynamic range (MPHDR) display system for use in vision research. The MPHDR display is the first system to our knowledge to allowfor spatially controllable, high dynamic range stimulus generation using multiple primaries.We demonstrate the high luminance, high dynamic range, and wide color gamut output of the MPHDR display. During characterization, the MPHDR display achieved a maximum luminance of 3200 cd=m2, a maximum contrast range of 3; 240; 000 V 1, and an expanded color gamut tailored to dedicated vision research tasks that spans beyond traditional sRGB displays. We discuss how the MPHDR display could be optimized for psychophysical experiments with photoreceptor isolating stimuli achieved through the method of silent substitution. We present an example case of a range of metameric pairs of melanopsin isolating stimuli across different luminance levels, from an available melanopsin contrast of117%at 75 cd=m2 to a melanopsin contrast of23%at 2000 cd=m2.

Original publication

DOI

10.1364/JOSAA.384022

Type

Journal article

Journal

J Opt Soc Am A Opt Image Sci Vis

Publication Date

01/04/2020

Volume

37

Pages

A271 - A284